Warning! This is a patch. Please consult with support before installation if you have any questions.
3.1.0.18499 Video Management System
PUBLISHED 30 May 2018
Release Notes:
- Improvements:
- Compression factors for Arecont Vision are tuned. FPS counter should be just as configured in Camera Settings.
- Audio output over RTSP support for Digital Watchdog cameras.
- "Camera recording" action at event rules now has 9999 seconds limit instead of 3600.
- H265 support is added for Digital Watchdog DWC-MTT4Wi36.
- Nx Desktop now shows warning if User is trying to record to Removable Drive(USB).
- Hikvision 5.5+ ONVIF automatic re-enabling
- "Do HTTP Request" action improvements. Now user can specify request and autorization type manually.
- DWC-PVX16W, DWC-PVX16W4, DWC-PVX16W6, DWC-PVX16W28, DWC-PZ21M69T multisensor cameras now have stitched view
- 2-way audio support for Sony cameras: SNC-VM600, SNC-VM630, SNC-VM641, SNC-VB632, SNC-VB642, SNC-WR632, SNC-WR602, SNC-WR630, SNC-EM641
- Advanced PTZ support is added for Vista VK2-HD30-PM, Hikvision DS-2DE4220W, DS-2DE4220IW, DS-2DP1636ZIX-D, DS-2DE7330IW, UNIVIEW IPC6253SR-X33 and Securicorp SCL-SDM03MVIR-WD3533X.
- "Access-Control-Allow-Origin: *" HTTP header added to hls response.
- Arecont Vision cameras AV12275 and AV12276 fps limits are increased to 10.
- Analog Encoder licenses support for Acti V23, Uniview NVR302-16S-P16, Sony SNT-EX104, SNT-EX154, SNT-EP154, Dahua DHI-HCVR7108H.
- LDAP-fetched administrators now can modify LDAP settings and users.
- New Device Support:
- Axis Q6214, M5054, D2050, Q6124, M5054, D2050, P1367, P1368, F40-Q1765, XF60-Q1765, P40-Q1765, F34, FA54, M5525, Q8742, P1275, Q8741, FA1105, FA4115, P1245, P1265, F1004, M3048, F8804, P3375, F4005, F1025, F1005, Q3517, Q8685, P3374, FA1125, F1015, F1035, Q3504, Q8642, Q8641, XF60-Q2901, XP40-Q1942, XF40-Q2901, P1447, Q3515, M5065, M3058, M3015, P1290, Q6125, M3057, Q1645, Q1647, M5055, M3016, P1280
- Arecont Vision AV08ZMD-300, AV02CLD-100, AV02CLB-100, AV05CLB-100, AV02CMB-100, AV05CMB-100, AV02CID-100, AV05CID-100, AV08CPD-118, AV20CPD-118
- Hikvision DS-7216
- UI changes:
- "Delete layout tour" is renamed to "Delete Showreel".
- "Showreel cycle" is renamed to "Tour cycle".
- Bug Fixes:
- Improper channels mapping fixed for encoders Hikvision DS-6716HQHI-SATA, Uniview NVR302-16S-P16, NVR302-08S-P8
- Server is not allowed to record to Removable Drives(e.g. USB). Fixed.
- Cameras with same IP addresses could not be added to merged servers. Fixed.
- Network Storage Drive had a chance to be initialized first. Now Local Drives are always initialized first.
- Fullscreen archive playback might cause high network usage for a long time. Fixed.
- UDP stream recording could stop after some time although live view is ok. Fixed.
- Advanced settings are not shown as a web-page for DW-CPRO cameras. Fixed.
- "No Signal" error for Hikvision 2CD6362F-I, DS-6704HFI, DS-2DF6223-CX. Fixed.
- RTSP streams from VLC couldn't be viewed in Nx. Fixed.
- Issues with French language on the Timeline.
- Various Server crashes are fixed.
- Local Drives disappear from Storage Management dialog or get disabled after Media Server restart. Fixed.
- Connectivity issues with Axis Cameras opened in Cloud Web Client. Fixed.
- DW cameras shown "404" error instead of web-page at the "Advanced" tab. Fixed.
- DTV cameras caused severe memory leaks at Media Server. Fixed.
- Cameras added as Generic RTSP links reappeared instantly after removal. Fixed.
- DWC-PB6M4T camera improperly worked after autodiscovery. Fix was tested with firmware ver. 1.0.4.030b, Build at 2017-01-24.
- "User Settings" window appeared below "System Administration" dialog in Mac OS X. Fixed.
- Several interface windows were always "on top" in Mac OS X. Fixed.
- "Offline" tiles couldn't be removed from the login screen. Fixed.
- Slight API documentation fixes.
- Multisensor Hikvision cameras were added as a single sensor. Fixed.
- Server sometimes responded 401 to API calls with proper auth data. Fixed.
- Failover priority worked improperly. Fixed.
- Sanyo camera RTSP stream didn't work in Nx. Fixed.
- "Enable audio" option was available for Axis cameras without audio support. Fixed.
- Server added only single stream from Axis Q6000. Now all 4 sensors can be added.
- Fixed outdated documentation and test tool for /api/mergeSystems method.
- Archive backup bandwidth limit did not work for local drives. Fixed.
- Server failed to add NAS with domains specified in username. Fixed.
- Videowall improperly detected screens geometry if windows reported more than 6 displays plugged. Fixed.
- Server did not add Axis P3707 camera after the successful search. Fixed.
- Audit trail does not log unsuccessful login attempts. Fixed.
- Different UI and User manual translation issues are fixed.
- RTSP stream generated by VLC player could not be properly replayed. Fixed.
- In multi-server systems camera could be recorded to several servers simultaneously. Fixed.
- Digital Input/Output signals had inverted values for Hikvision DS-2DE4A220IW-DE, DS-2CD2522FWD, DS-2CD2142FWD-IWS and OEMed versions. Fixed.
- Multichannel cameras had incorrect resolution "Information" overlay in 2x2 mode. Fixed.
- No audio from Acti cameras of AB2L platform. Fixed.
- Axis horn speakers failed to work after upgrade to 3.1. Fixed.
- Local time synchronization might misbehave if CPU clocks are imprecise. Fixed.
- Dahua DH-SD22404T-GN PTZ did not follow in-client joystick commands. Fixed.
- DWC-PF5M1TIR, DWC-PB6M4T, DWC-MB45DiA, DWC-MV85DiA sent notification with wrong port number, fixed on the server side.
- Uniview DVS4116 autodiscovered information was incorrect. Fixed.
- Dragging zoom window between ultra-widescreen and normal camera caused aspect ratio misbehavior. Fixed.
- Sound from some cameras were played back with distortions on high frequencies. Fixed.
- Breaking changes:
- Lite Client is removed from Nx1 build for overall stability improvement.
In-Client Upgrade:
Build Number: | | 18499 |
Password: | | 1o4177 |
Download Links: